Peak reflectivity measurements of W/C, Mo/Si, and Mo/B4C multilayer mirrors in the 8–190-Å range using both Kα line and synchrotron radiation

Not Accessible

Your library or personal account may give you access

Abstract

Peak reflectivity measurements of W/C, Mo/Si, and Mo/B4C multilayer mirrors have been performed using line and synchrotron radiation in the 8–190 Å wavelength range. Short wavelength measurements using a line source were corrected for nonmonochromatic and divergent incident radiation. Reflectivities of Mo/Si mirrors, measured with synchrotron radiation, ranged from 25 to 44% but decreased significantly around the Si absorption edge. Mo/B4C multilayer mirrors were measured that had peak reflectivities from 10 to 25% between 90 and 200 Å and bandpasses as small as 3 Å.

© 1990 Optical Society of America

Full Article  |  PDF Article
More Like This
Near normal incidence spectroscopy of a Penning ionization discharge in the 110–180 Å range with flat multilayer mirrors

Michael Finkenthal, Andrew P. Zwicker, Sean P. Regan, H. Warren Moos, and Dan Stutman
Appl. Opt. 29(24) 3467-3469 (1990)

Mo/B4C/Si multilayer-coated photodiode with polarization sensitivity at an extreme-ultraviolet wavelength of 13.5 nm

Benjawan Kjornrattanawanich, Saša Bajt, and John F. Seely
Appl. Opt. 43(5) 1082-1090 (2004)

Normal-incidence reflectance of W/B4C multilayer mirrors in the 34–50-Å wavelength region

J. F. Seely, G. Gutman, J. Wood, G. S. Herman, M. P. Kowalski, J. C. Rife, and W. R. Hunter
Appl. Opt. 32(19) 3541-3543 (1993)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (4)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved