Abstract
The refractive index of germanium was measured for ten samples, covering the various crystal types, over the 8–14-μm wavelength range. Samples were obtained from several suppliers, and differences between samples in the index values reported were not significant compared with the estimated index uncertainties of ±0.0003. Three samples were examined at two laboratories to act as a check on the absolute values obtained. A temperature coefficient index of 0.00040°C−1 was obtained for the 20–25°C range.
© 1982 Optical Society of America
Full Article | PDF ArticleMore Like This
R. P. Edwin, M. T. Dudermel, and M. Lamare
Appl. Opt. 17(7) 1066-1068 (1978)
John H. Burnett, Eric C. Benck, Simon G. Kaplan, Erik Stover, and Adam Phenis
Appl. Opt. 59(13) 3985-3991 (2020)
D. L. Wood and K. Nassau
Appl. Opt. 21(16) 2978-2981 (1982)