Two techniques, focal spot projection and fringe projection, have been developed for profiling the edges of anterior-chamber style intraocular lenses (IOL). The techniques are based on measurement of the trajectory of reflected light when an incident beam is focused and stepped across the edge surface (spot projection) or when two focused beams combine to form an optical interference pattern on the edge (fringe projection). The optical configurations for performing the projection techniques are described along with the mathematical relationship between the reflected-beam trajectories and the edge profile. An automated system for the implementation of focal spot projection was developed. The system has the capability of positioning the IOL edge at the focal point of the incident beam, acquiring trajectory data via stepper motors and a TV camera, processing the data to generate a profile, and displaying the profile on the computer video monitor or in hard-copy form via a printer. On one lens tested, three profiles corresponding to different locations along the IOL edge could be generated without user intervention. However, the user has the option of manually positioning the IOL to permit greater versatility. The typical 300-μm wide IOL edges are profiled to a resolution of ~20 μm. To constrain optical and microprocessor hardware costs, compromises were made in operating speeds so that ~20 min is required per profile. With current trends in integrated circuit technology future generations of the system could be made faster and prove useful as a QC tool for the IOL industry. Furthermore, the present device can be used in determining appropriate IOL profile standards.

© 1982 Optical Society of America

Full Article  |  PDF Article
More Like This
Inspection of freeform intraocular lens topography by phase measuring deflectometric methods

Alexis Speck, Benedikt Zelzer, Marc Kannengießer, Achim Langenbucher, and Timo Eppig
Appl. Opt. 52(18) 4279-4286 (2013)

Triplet design as an intraocular lens for high myopia

C. González, L. Carretero, I. Pascual, and A. Fimia
Appl. Opt. 34(16) 2898-2907 (1995)

Immersionless single-mode preform index profiling

Herman M. Presby and Dietrich Marcuse
Appl. Opt. 21(23) 4253-4259 (1982)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (18)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (18)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.