Stable Operation of All-Optical Fibre Photoacoustic Sensors

Not Accessible

Your library or personal account may give you access

Abstract

Stable operation of graphene-diaphragm based fiber-tip photoacoustic gas sensor is achieved by use of a modified Sagnac interferometer with a 3x3 coupler. A detection limit of 1.5 ppm of C2H2 balanced with 𝑁2 is demonstrated and the system stability is <0.4 dB over 6 hours.