Abstract
A way to increase the optical monitoring sensitivity in quarterwave stack fabrication by modified optical admittance loci was demonstrated. The optical admittance value was obtained from an in-situ dynamic interferometer combing with a photodetector, and the result was compared with ellipsometer measurement.
© 2010 Optical Society of America
PDF ArticleMore Like This
Yu-Ren Chen and Cheng-Chung Lee
WC7 Optical Interference Coatings (OIC) 2007
Boo-Young Jung, Jang-Hoon Lee, Sung-Goo Jung, Byung Jin Chun, Chang Kwon Hwangbo, Young-Jin Song, Eung-Soon Kim, and Jong Sup Kim
WC1 Optical Interference Coatings (OIC) 2007
K. Wu, Y. H. Liu, and C. C. Lee