Abstract
A critical test is proposed to determine if a diaphragm fiber optic sensor (DFOS) is interference or intensity based. Using the criterion, the first purely Fabry-Perot DFOS has been designed, fabricated with MEMS technology, and characterized with orders of improvement of signal-to-noise ratio.
© 2006 IEICE
PDF ArticleMore Like This
S. Poeggel, D. Tosi, G. Leen, and E. Lewis
CH_3_5 The European Conference on Lasers and Electro-Optics (CLEO/Europe) 2013
H. Latifi, S. H. Aref, M. Afshari, and M. I. Zibaii
TuE51 Optical Fiber Sensors (OFS) 2006
Mingran Quan, Zejin Lu, Jiajun Tian, and Yong Yao