Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Long Time Operation of Composite Ceramic Nd:YAG/Cr:YAG Micro-chip Lasers for Ignition

Not Accessible

Your library or personal account may give you access

Abstract

Life tests of diode pumped, high peak power, passively Q-switched composite ceramic Nd:YAG/Cr:YAG micro-chip lasers were performed. Output energy of 3mJ with a pulse duration of <1ns and a repetition rate of 20Hz had been maintained over 8,000hs at room temperature without degradation. We had also confirmed over 7,000hs operation with a repetition rate of 80Hz at room temperature, and with 20Hz at 90 degree C.

© 2015 Optical Society of America

PDF Article
More Like This
Laser Performance of Composite Nd:YAG/Cr:YAG Ceramics for Laser Ignition

Masaki Tsunekane and Takunori Taira
C433 Conference on Lasers and Electro-Optics/Pacific Rim (CLEO/PR) 2011

Passively Q-switched Nd:YAG/Cr4+:YAG All-Ceramics, Composite, Monolithic Micro-Lasers with Multi-Beam Output for Laser Ignition

N. Pavel, M. Tsunekane, and T. Taira
CA7_1 The European Conference on Lasers and Electro-Optics (CLEO/Europe) 2011

Composite All-Ceramics, Passively Q-switched Nd:YAG/Cr4+:YAG Monolithic Micro-Laser with Two-Beam Output for Multi-Point Ignition

N. Pavel, M. Tsunekane, K. Kanehara, and T. Taira
CMP1 CLEO: Science and Innovations (CLEO:S&I) 2011