Novel method for non-invasive blood pressure measurement from the finger using an optical system based on dynamic light scattering

Not Accessible

Your library or personal account may give you access

Abstract

Self-measurement of blood pressure (BP) is important for monitoring treatment of hypertension, but current instruments are cumbersome and at times also impractical, especially for the older population. Current optical solutions, such as PPG-based technologies that were developed for improving convenience, provide derived measurements that are often inaccurate, particularly for diastolic values. Alternatively, by using dynamic light scattering (DLS) we are able to measure the direct hemodynamic response. We propose a simple physical model that explains the relation between arterial pressure values and the hemodynamic response which is measured from the finger root following changes in externally applied pressure. Based on this model we have developed a small-scaled, optical, mobile device that measures BP at the finger using dynamic light scattering. The apparatus is positioned at the base of the index finger and contains a ring with an inflatable cuff with two miniaturized dynamic light scattering (mDLS) sensors situated distal to the cuff. The cuff is inflated to above systolic pressure, and changes in blood flow (hemodynamics) are measured during cuff deflation. BP measurement is carried out using specially designed algorithms based on hemodynamic indexes and waveform analysis which capture systolic and diastolic points in real-time. Using this apparatus, we measured BP from 69 patients visiting a hypertension outpatient clinic, and a control group of 15 healthy subjects. BP readings were compared with measurements recorded at the arm location with an Omron device used in the clinic. The mean absolute error (MAE) for systolic and diastolic blood pressure was 7.8 and 9 mmHg, respectively at all ranges of BP measured. In conclusion, using Elfi-Tech's innovative technology, it is possible to measure BP accurately at the finger location using a compact, convenient mDLS-based device with high accuracy.

© 2019 SPIE/OSA

PDF Article
More Like This
Wearable Smartwatch based on Optical Fiber for Continuous Blood Pressure Monitoring.

Liangye Li, Yunfei Liu, Shunfeng Sheng, Changying Song, Wei Fan, and Qizhen Sun
W2A.14 Optical Fiber Communication Conference (OFC) 2022

Use of dynamic light scattering for assessing acute pain

Suzanne Broens, Adi Schejter Bar-Noam, Ilya Fine, Louis Shenkman, Monique van Velzen, Marieke Niesters, and Albert Dahan
11075_21 European Conference on Biomedical Optics (ECBO) 2019

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved