In-situ monitoring of blood glucose level for dialysis machine by AAA-battery-size ATR Fourier spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

For blood glucose level measurement of dialysis machines, we proposed AAA-battery-size ATR (Attenuated total reflection) Fourier spectroscopy in middle infrared light region. The proposed one-shot Fourier spectroscopic imaging is a near-common path and spatial phase-shift interferometer with high time resolution. Because numerous number of spectral data that is 60 (= camera frame rare e.g. 60[Hz]) multiplied by pixel number could be obtained in 1[sec.], statistical-averaging improvement realize high-accurate spectral measurement. We evaluated the quantitative accuracy of our proposed method for measuring glucose concentration in near-infrared light region with liquid cells. We confirmed that absorbance at 1600[nm] had high correlations with glucose concentrations (correlation coefficient: 0.92). But to measure whole-blood, complex light phenomenon caused from red blood cells, that is scattering and multiple reflection or so, deteriorate spectral data. Thus, we also proposed the ultrasound-assisted spectroscopic imaging that traps particles at standing-wave node. Thus, if ATR prism is oscillated mechanically, anti-node area is generated around evanescent light field on prism surface. By elimination complex light phenomenon of red blood cells, glucose concentration in whole-blood will be quantify with high accuracy. In this report, we successfully trapped red blood cells in normal saline solution with ultrasonic standing wave (frequency: 2[MHz]).

© 2015 SPIE

PDF Article
More Like This
Ultrasonic-Assisted Blood Glucose Monitoring using Mid-Infrared Spectroscopy

Hiroyuki NOMURA, Keita MORI, Natsumi KAWASHIMA, Tomoya KITAZAKI, Akira NISHIYAMA, Kenji WADA, and Ichiro ISHIMARU
JM4A.9 3D Image Acquisition and Display: Technology, Perception and Applications (3D) 2018

Detection of Blood Glucose Level in Mice using Ultrasonic-assisted Mid-infrared Fourier Spectroscopy for realizing Earring-type Non-invasive Blood Glucose Sensors

Natsumi KAWASHIMA, Tomoya KITAZAKI, Hiroyuki NOMURA, Akira NISHIYAMA, Kenji WADA, and Ichiro ISHIMARU
JM4A.2 3D Image Acquisition and Display: Technology, Perception and Applications (3D) 2018

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.