Measurement of the acoustic scatterers distribution within the imaged sample in an optoacoustic tomographic setup

Not Accessible

Your library or personal account may give you access

Abstract

We present in this work a method to estimate the distribution of acoustic scatterers within the imaged sample in an optoacoustic tomographic setup and, subsequently, to reduce the artefacts in the tomographic reconstructions due to reflection or scattering events. The procedure to determine the position of the scatterers consists of measuring the scattered waves generated at a point light absorber located in between the transducer and the imaged sample. Such absorber is positioned in a way that the acoustic waves generated at this absorber and scattered within the sample arrive at the position of the transducer after the waves generated within the sample that propagate directly until the measuring point. Then, the signals captured by the acoustic transducer can be used to reconstruct the distribution of acoustic scatterers and to perform the optoacoustic reconstruction itself. Also, the information retrived on the distribution of acoustic scatterers can be used to improve the optoacoustic tomographic reconstructions. For this, we use a modification of the filtered back-projection algorithm based on weighting the signals with the probability that they are not affected by scattered or reflected waves, so that the artefacts in the images due to these acoustic phenomena are reduced. The experimental results obtained with a tissue-mimicking phantom in which a straw filled with air was included in order to cause scattering of the acoustic waves indicate a good performance of the method proposed.

© 2011 OSA/SPIE

PDF Article
More Like This
Weighted reconstruction methodology for optoacoustic tomographic imaging of heterogeneous acoustic samples

X Lúıs Déan-Ben, Vasilis Ntziachristos, and Daniel Razansky
88000J European Conference on Biomedical Optics (ECBO) 2013

Time-shifting correction in optoacoustic tomographic imaging for media with non-uniform speed of sound

X Lúıs Deán-Ben, Vasilis Ntziachristos, and Daniel Razansky
809013 European Conference on Biomedical Optics (ECBO) 2011

Correction for acoustic attenuation effects in optoacoustic tomographic reconstructions

X Lúıs Deán-Ben, Daniel Razansky, and Vasilis Ntziachristos
809014 European Conference on Biomedical Optics (ECBO) 2011

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.