Evaluation of image reconstruction algorithm for near infrared topography by virtual head phantom

Not Accessible

Your library or personal account may give you access

Abstract

The poor spatial resolution and reproducibility of the images are disadvantages of near infrared topography. The authors proposed the combination of the double-density probe arrangement and the image reconstruction algorithm using a spatial sensitivity profile to improve the spatial resolution and the reproducibility. However, the proposed method was evaluated only by the simplified adult head model. It is uncertain whether the proposed method is effective to the actual head that has complicated structure. In this study, the proposed method is evaluated by the virtual head phantom the 3D-structure of which is based upon an MRI scan of an adult head. The absorption change the size of which is almost equivalent to the width of the brain gyri was measured by the conventional method and the proposed method to evaluate the spatial resolution of the topographic images obtained by each method. The positions of the probe arrangements are slightly changed and the topographic images of the same brain activation measured by two probe positions are compared to evaluate the reproducibility of the NIR topography. The results indicate that the combination of the double-density probe arrangement and the image reconstruction algorithm using the spatial sensitivity profile can improve both the spatial resolution and the reproducibility of the topographic image of brain activation in the virtual head phantom. However, the uneven thickness of the superficial tissues affects the accuracy of the position of activation in the images.

© 2007 SPIE

PDF Article
More Like This
Normalized Adult Head Model for the Image Reconstruction Algorithm of NIR Topography

Hiroshi Kawaguchi and Eiji Okada
BSuE38 Biomedical Optics (BIOMED) 2008

A Head Phantom for Use in Near Infrared Topography for Brain Function Measurements

Hirokazu Kakuta, Hiroshi Kawaguchi, and Eiji Okada
JMA58 Biomedical Optics (BIOMED) 2010

Phantom experiments for quantitative evaluation of topographic image by mapping algorithm

Yusuke Yoshida, Hirokazu Kakuta, Hiroshi Kawaguchi, and Eiji Okada
80881D European Conference on Biomedical Optics (ECBO) 2011

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.