Cerebral Oxygenation Monitoring during Cardiac Bypass Surgery in Infants with Broad Band Spatially Resolved Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Neurological impairments following cardio-pulmonary bypass (CPB) during open heart surgery can result from microembolism and ischaemia. Here we present results from monitoring cerebral haemodynamics during CPB with near infrared spatially resolved broadband spectroscopy. In particular, the study has the objective (a) to monitor oxy- and deoxyhemoglobin concentrations (oxy-Hb, deoxy-Hb) and their changes as well as oxygen saturation during CPB surgery and (b) to develop and test algorithms for the calculation of these parameters from broad band spectroscopy. For this purpose a detection system was developed based on an especially designed lens imaging spectrograph with optimised sensitivity of recorded reflectance spectra for wavelengths between 600 and 1000 nm. The high f/#-number of 1:1.2 of the system results in about a factor of 10 higher light throughput combined with a lower astigmatism and crosstalk between channels when compared with a commercial mirror spectrometers (f/# = 1:4). For both hemispheres two independent channels each with three source-detector distances (ρ = 25 – 35 mm) were used resulting in six spectra. The broad band approach allows to investigate the influence of the wavelength range on the calculated haemoglobin concentrations and their changes and oxygen saturation when the attenuation A(λ) and its slope ΔA(λ)/Δρ are evaluated. Furthermore, the different depth sensitivities of these measurement parameters are estimated from Monte Carlo simulations and exploited for an optimization of the cerebral signals. It is demonstrated that the system does record cerebral oxygenation parameters during CPB in infants. In particular, the correlation of haemoglobin concentrations with blood supply (flow, pressure) by the heart-lung machine and the significant decreases in oxygen saturation during cardiac arrest is discussed.

© 2007 SPIE

PDF Article
More Like This
Muscle Oxygenation during exercise under hypoxic conditions assessed by spatial-resolved broad-band NIR spectroscopy

Dmitri Geraskin, Petra Platen, Julia Franke, Christiane Andre, Wilhelm Bloch, and Matthias Kohl-Bareis
WE4 European Conference on Biomedical Optics (ECBO) 2005

Monitoring Cerebral Blood Flow And Oxygenation During Cardiac Surgery

Parisa Farzam, Stefan Carp, Juliette Selb, Parya Farzam, Melissa Wu, Maria A. Franceschini, and Jason Z. Qu
BTh2C.7 Optics and the Brain (BRAIN) 2018

Evaluation of muscle oxygenation based on spatial-resolved broad band and time-resolved spectroscopy

Oliver Rohm, Roland Gürtler, and Matthias Kohl-Bareis
SH2 Biomedical Topical Meeting (BIOMED) 2004

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved