Nanosecond contrast of the Orion CPA beamlines is enhanced from 10−8 to 10−10 by inserting a picosecond OPA prior to the stretcher. In conjunction with frequency doubling post-compression this will enhance the contrast to ~10−18.
© 2014 Optical Society of America
PDF ArticleMore Like This
F. Wagner, C. P. João, J. Fils, T. Gottschall, J. Hein, J. Körner, J. Limpert, M. Roth, T. Stöhlker, and V. Bagnoud
CG_4_4 The European Conference on Lasers and Electro-Optics (CLEO/Europe) 2013
W. Shaikh, I. O. Musgrave, C. Hernandez-Gomez, B. Parry, and D. Johnson
ATuA18 Advanced Solid-State Photonics (ASSL) 2010
S. P. Elsmere, T. Bett, C. Danson, S. Duffield, D. Egan, M.T. Girling, E. Harvey, D.I. Hillier, N. Hopps, D. Hoarty, D. Hussey, M. Norman, S. Parker, P. Treadwell, and D. Winter.