Abstract
An integrated optical refractometer based on multimode interference, with sensitivity enhancement due to sub-micrometer axial features, is demonstrated with experimental sensitivity as high as 3200 nm/RIU and resolution limits on the order of 5 ppm.
© 2011 Optical Society of America