Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference and Photonic Applications Systems Technologies
  • OSA Technical Digest (CD) (Optica Publishing Group, 2008),
  • paper CMEE2

High-Accuracy Interferometer with a Prism Pair for Measurement of the Absolute Refractive Index of Glass

Not Accessible

Your library or personal account may give you access

Abstract

Interferometer for precise refractive-index measurement of glass-prism without prior knowledge is developed using a direct comparison of optical-path-changes in glass and air. Preliminary result shows uncertainty of 4.4 × 10–5 agreeing with the manufacturer’s values.

© 2008 Optical Society of America

PDF Article
More Like This
Quadrature Detection and Cancellation of Absolute Wavelength in a Prism-Pair Interferometer for High-Accuracy Refractive Index Measurements of Glasses

Yasuaki Hori, Akiko Hirai, and Kaoru Minoshima
JThE84 Conference on Lasers and Electro-Optics (CLEO:S&I) 2009

Prism-pair Interferometer for Precise Refractive Index Measurement using Spectral Lamp Radiation with Simultaneous Wavelength Calibration

Yasuaki Hori, Akiko Hirai, and Kaoru Minoshima
CTuOO4 Conference on Lasers and Electro-Optics (CLEO:S&I) 2010

A folded low-coherence interferometer for high-accuracy measurement of group refractive index

A. Hirai, K. Sasaki, and H. Matsumoto
CTuO2 Conference on Lasers and Electro-Optics (CLEO:S&I) 2004

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved