Unstable resonator for large aperture, photoswitched XeCl laser

Not Accessible

Your library or personal account may give you access

Abstract

A large volume (10 × 9.5 × 100 cm3), x-ray triggered, self-sustained discharge pumped XeCl laser has been operated with a positive branch unstable resonator (PBUR). An output energy of 5 J on 8 × 9 cm2 transverse cross-section with a pulse duration of 100 ns (FWHM) was obtained with a magnification M = 7 (defined as the ratio between the radii of curvature of the two aluminized mirrors); this result must be compared with an output energy equal to 8 J on the same cross-section with a pulse length of 140 ns of an optimized plano–plano cavity.1

© 1992 Optical Society of America

PDF Article
More Like This
Further Studies of Large Aperture XeCl Laser Performance

B. L. Wexler and R. L. Burnham
MB3 Excimer Lasers (EL) 1983

Special features of using an unstable resonator in XeCl laser with aperture 12 × 16 cm2

N. G. Ivanov and V. F. Losev
CTuK105 The European Conference on Lasers and Electro-Optics (CLEO/Europe) 1994

Wide Aperture Self-Sustained Discharge KrF and XeCl Lasers

S. Watanabe, A. Endoh, and M. Watanabe
MB2 Excimer Lasers (EL) 1983