Abstract
A low liquid velocity sensor composed by a capillary vertically inserted in PTFE (Polytetrafluoroethylene) tube has been proposed and realized with high sensitivity. The achieved sensitivity to liquid velocity is 0.0016nm/( μL/min ).
© 2018 The Author(s)